Q: Fi fun P₀ ati Pₖ lati awọn idanwo, bawo ni MO ṣe ṣe iṣiro ṣiṣe ni awọn ipele fifuye oriṣiriṣi?
A: Iṣẹ ṣiṣe η=P_out / (P_out + P₀ + ² × Pₖ) × 100%, nibiti=ifosiwewe fifuye.
Apeere: 10 MVA transformer, P₀=12 kW, Pₖ=85 kW:
|
Fifuye |
|
Ijade (kW) |
P₀ (kW) |
²×Pₖ (kW) |
η (%) |
|
25% |
0.25 |
2,500 |
12 |
5.3 |
99.31 |
|
50% |
0.50 |
5,000 |
12 |
21.3 |
99.34 |
|
75% |
0.75 |
7,500 |
12 |
47.8 |
99.21 |
|
100% |
1.00 |
10,000 |
12 |
85.0 |
99.04 |
|
120% |
1.20 |
12,000 |
12 |
122.4 |
98.89 |
Iṣiṣẹ ti o pọju ni=√(P₀ / Pₖ)=0.376 → ~37.6% fifuye.
Awọn iṣedede agbara agbara:
• IEC 60076-20: Awọn kilasi EEI A (ti o ga julọ) → D.
• EU Ecodesign 2019/1783: Ipele 2 (2021), Ipele 3 (2025-27).
• DOE 10 CFR Apá 431: Ofin tuntun ti o munadoko ni Oṣu Karun ọjọ 2026.
• GB 20052-2020 (China): Ipele 1 (ti o ga julọ) → 3.
• IS 1180 (India): BEE Star Rating 1–5.
Ọna TCO: TCO= Iye + A × P₀ + B × Pₖ
A ≈ $3,000–8,000/kW (ko -iye owo nla fifuye).
B ≈ $500–2,000/kW (iye owo nla fifuye).