Q: Mo nilo lati ṣe idanwo okun 220 kV, 8 km gigun. Iwọn SR wo ni Mo nilo?

 

A: Ilana iwọn-igbesẹ 7: pinnu awọn ibeere idanwo → iṣiro C → iṣiro L → iṣiro f_res → ṣayẹwo awọn iwọn → iterate → ipari.

Igbesẹ -nipasẹ-Igbese - 220 okun kV, 8 km:

1. IEC 60840: V_igbeyewo=2.0 × 127 kV=254 kV. Iye akoko 60 min.

2. C ≈ 8 km × 0.2 μF/km=1.6 μF.

3. Ro 3× 100 kV/2 A reactors ni afiwe: L=26.7 H, f=24.4 Hz.

4. Lọwọlọwọ ni 254 kV: I=V × 2πf × C=6.9 A. Ṣugbọn 3×2A → 6A lapapọ → KO DARA.

5. Igbesoke si 3× 100 kV/4 A reactors: lapapọ I=12 A → O dara. P_in=254×6.9/35=50 kW.

6. Apapọ iwuwo: 3×450 kg + 200 + 150 + 100=~1,800 kg.

 

Akopọ iwọn fun awọn oju iṣẹlẹ ti o wọpọ:

Oju iṣẹlẹ

V_igbeyewo (kV)

C (μF)

f (Hz)

Niyanju System

33 kV okun, 3 km

48

0.6

45

60 kV/2A ×1, 5 kW

110 kV okun, 5 km

160

1.0

24

200 kV/4A ×2, 20 kW

220 kV okun, 8 km

254

1.6

24

300 kV/4A ×3, 50 kW

400 kV okun, 5 km

330

1.0

48

400 kV/2A ×2, 25 kW

GIS 245 kV, 10 bays

230

0.05

80

300 kV/1A ×2, 5 kW

monomono 100 MVA

28

2.5

45

30 kV/5A, 10 kW

 

Awọn olurannileti to ṣe pataki:

• +20% ala lori oṣuwọn foliteji reactor . +30% ala lori idiyele lọwọlọwọ.

• Ti P_in> 100 kW, ronu idanwo apakan (a gba laaye nipasẹ ọpọlọpọ awọn iṣedede).

• gangan Q le dinku ju ifoju - igbero Konsafetifu yago fun awọn ikuna aaye.